Technical parameters
- Control range: -50 ~ 110Input Power: DC 12VResolution: -9.9-99.9 0.1 , other temperature ranges 1Measuring inputs: NTC (10K 0.5%) Waterproof sensor 0.5MMasurement accuracy: 0.1Output range: 1 way 10A relayControl accuracy: 0.1Environmental requirements: -10-60 , humidity 20% -85%Hysteresis accuracy: 0.1Size: 48 * 40mmRefresh rate : 0.5SPower consumption: Static current: <= 35MA,attract current:<= 65MATemperature protection :0-110Display Type: 0.28 " three digital display tube
How to use:
- Connect the power supply and the load, you can supply to the controller, Is displayed as a measured temperature, Press the SET button, the display flashes the temperature, Press + - to set the desired temperature, After setting press SET to confirm return, The controller automatically performs the relay by setting off!Lights, LED status descriptions:Indicator: Off The relay is switched off, Always indicate the relay is closed.LED: Shows LL is the sensor open, showing HH is out of range, the thermostat will be forced to close the relay, the display --- as high temperature protection.Parameter Function: Long press SET 5 seconds to enter the main menu settings, press the + - toggle P0 ... P8 long press SET or 10 seconds of no key activity confirmed their return to the controller
Code Code Description Setting range Factory settingP0 Cooling /Heating C/H CP1 Hysteresis setting 0.5-15 2